Logger meters I1L, I2L, I4L, I8L

Price
3,000 UAH
Availability
In stock

Panel logger meters I1L, I2L, I4L, I8L are designed to store measured values in the instrument's non-volatile memory at specified time intervals. They can be configured as single-channel, two-channel, four-channel, and eight-channel meters [...]

Back to catalog

Specifications

Description

Logger meters I1L, I2L, I4L, I8L are designed for measuring input signals and storing their values in the instrument's non-volatile memory (up to 10,000 records) at specified time intervals (from 1 to 9999 min) on one, two, four, or eight channels.
I1L, I2L, I4L, I8L allow performing the following functions:
- measuring parameters of various objects using standard sensors (resistance temperature detectors (temperature sensors) TSM (50M, 100M) and TSP (50P, 100P, Pt100), thermocouples (TXK, TXA, TJK, etc.), sensors with standardized current output signals (0..5mA, 0..20mA, 4..20mA) and voltage (0..1V, 0..10V));
- displaying measured values on the indicator;
- psychrometric method for humidity measurement (second channel function for I2L);
- data exchange with PC via RS-485 interface (by default);
- generation of "Error" signal;
- output of alarm signaling;
- software change of conversion characteristics parameters.

Manufacturing Modifications of I1L, I2L, I4L, I8L

  • number of channels: 1, 2, 4, 8;
  • model with liquid crystal display or with four-digit seven-segment indicators;
  • powered from 220V AC mains or from 12..24V DC source;
  • input signal types: UV (universal input), TO, PT, AN and AT;
  • types of alarm output devices: R, OC, OS.

Additional information

Modifications

Modifications of panel meters and controllers with logger function
T[N1]-01L [N2]TO,[N3]PT,[N4]ANx,[N5]ATx/[N6]OC,[N7]R,[N8]OC,[N9]ANx,[N10]ATx-2I-RS-485 -IPx–Panel
RP1L – 1TC/1AN2-2I-RS-485–IPI–Panel
RP 1 L 1TC 1AN2 2I RS-485 IPI Panel
Device type: I - meter RD - two-position controller RP - PID controller
[N1] - number of measurement/control channels: 1 - I1, RD1 and RP1 (with analog and discrete outputs) 2 - I2, RD2 and RP2 (with analog and discrete outputs) 3 - only RD3 4 - I4, RD4 and RP4 (only with discrete outputs) 8 - I8
01 - alarm output for two-channel meter
Logger function allows storing measured values (up to 10,000 records) in the meter's non-volatile memory at a set time interval (from 1 to 9999 minutes).
Number and types of input sensors: [N2] - number of TO [N3] - number of PT [N4] - number of sensors with AN (AN1 - 0 to 1 V; AN2 - 0 to 10 V; AN3 - 0 to 5 V) [N5] - number of sensors with AT (AT1 - 0 to 5 mA; AT2 - 0 to 20 mA; AT3 - 4 to 20 mA)
Number and types of output devices: [N6] - number of OC – open collectors [N7] - number of R - relays [N8] - number of OC – optocouplers [N9] – number of AN voltage outputs (AN1 - 0 to 1 V; AN2 - 0 to 10 V; AN3 - 0 to 5 V) [N10] - number of current outputs AT (AT1 - 0 to 5 mA; AT2 - 0 to 20 mA; AT3 - 4 to 20 mA)
Number of indicators: 2I - 2 four-digit seven-segment indicators
Interface with PC: RS-485 - added to all panel devices with logger function
Power supply type: IPI - powered from AC mains 90..240V IP24 - powered from DC source 12..24V
Case type: Panel

REGMIK

Downloads

FAQ

Questions and answers

How many records can logger meters I1L, I2L, I4L, I8L store?
Logger meters I1L, I2L, I4L, I8L can store up to 10,000 records of measured values in the instrument's non-volatile memory.
How many channels do models I1L, I2L, I4L, I8L support?
The device supports the number of channels: 1 (I1L), 2 (I2L), 4 (I4L), or 8 (I8L), allowing measurement of signals on the corresponding number of channels simultaneously.
What sensor types do logger meters I1L, I2L, I4L, I8L support?
The meters support various sensor types: resistance temperature detectors (TSM, TSP, Pt100), thermocouples (TXK, TXA, TJK, etc.), as well as sensors with standardized current output signals (0..5 mA, 0..20 mA, 4..20 mA) and voltage (0..1 V, 0..10 V).
What power supply do meters I1L, I2L, I4L, I8L support?
The devices can be powered either from 220V AC mains or from a 12..24V DC source, depending on the modification.
How is data exchange between the meter and PC performed?
Data exchange is performed via RS-485 interface, which is installed by default on all panel models with logger function.