REGMIK product

REGMIK SSD 10 data collection and device management system

Price
Price on request
Availability
In stock

REGMIK SSD 10 data collection and dispatch system: device connection, current indicators, measurement history, charts, alarms, and interactive mimic schemes. Work via web interface or iPhone and iPad app; control access depends on user rights.

Try demo mimic scheme of heat point without registration 14

Back to catalog

Specifications

Description

REGMIK SSD DATA COLLECTION AND DISPATCHING

From sensor reading to the whole process picture

REGMIK SSD Web Console combines devices, measurements, charts, and mimics schemes in one web interface. The system collects technological data, stores history, shows the current equipment status, and helps the operator respond to deviations.

Temperature, pressure, flow, level, and other parameters are available on cards, charts, and the scheme of your site. The solution can be configured for heat points, boiler rooms, refrigeration units, warehouses, or production areas with compatible equipment.

Try the demo mimic scheme 10 Open REGMIK SSD 11

Data collection and equipment connection

  • Unified object structure: domains, devices, and channels with their own names, units of measurement, polling periods, and storage parameters.
  • Modbus TCP and Modbus RTU: connection via Ethernet or serial COM port/RS-485 converter accessible to the server. Register map and descriptor must correspond to a specific device.
  • Additional sources: integrations with OPC UA and MQTT, file and FTP sources, reading archives of supported loggers. Edge agents are provided for remote sites.
  • Connection control: current values, update time, communication errors, and polling status help distinguish new measurements from outdated data.

Interactive mimic schemes - equipment on one screen

The built-in editor allows creating a visual scheme of the technological process. The library includes pumps, valves, tanks, heat exchangers, sensors, pipelines, indicators, indicator cards, and charts. Elements can be moved, scaled, grouped, and linked to channels.

  • Status in motion: direction and speed of flow, pump rotation, liquid level, and color rules display configured signals. Unavailable or outdated values should not be perceived as an active process.
  • Multiple schemes: separate tabs for installations or sites, layers and canvas settings for convenient object organization.
  • Check before launch: local simulation helps to verify the scheme without commands to real equipment. Test signals and real channels are assigned separately.
  • Configuration transfer: import and export schemes in JSON preserve geometry, design, rules, and animation. For another object, bindings to equipment are assigned anew.
  • "Mimic scheme only" mode: canvas proportionally fits into the window, and animation and available control continue to work.

History, charts, and analysis

View current indicators and archive for a selected period, compare channels, and assess the process reaction to mode changes. The server stores measurements in PostgreSQL. Measurements, errors, and event logs can be exported to CSV for further processing.

Alarms and notifications

Set permissible value limits, monitor response loss and communication errors. The log helps restore the sequence of events. Depending on server configuration, Telegram, email, webhook, SMS, and sound notifications are available; external channels require separate setup.

Device parameters, control, and access rights

REGMIK SSD allows reading and modifying parameters of compatible devices by descriptor, performing available manual commands, and transferring logger archives into a common history. Administrator, engineer, operator, and viewer roles delineate access; operations depend on device model and user rights.

Import and export of configuration, action log, and account settings help maintain the system. Ukrainian and English languages, themes, and various display modes allow adapting the workspace for the operator.

How it works

Devices and sensors 18 communication interface 18 REGMIK SSD server 18 browser or mobile app.

The server polls equipment and stores history, while the user works through the web interface. Cloud server or own installation can be used. Windows, macOS, and Debian installers prepared for local deployment. Commercial use requires license; check device compatibility, kit, and implementation terms at REGMIK.

Try REGMIK SSD: demo mimic scheme of a heat point

The demo opens without registration. You see a closed loop with a buffer tank, main and reserve pumps, heat exchanger, valve, and heat consumer. Temperature, flow, and pressure indicators change along with equipment state.

  1. Normal operation. Observe circulation and heating, change the temperature setpoint, and see the reaction on the chart.
  2. Peak load. Switch scenario and compare flow, temperature, and pump operation.
  3. Pump failure. Check indication of main pump fault and transition to reserve.
  4. Manual control. Click the pump, valve, and heat exchanger directly on the scheme or use buttons below. Closing the valve or stopping both pumps stops circulation and heating.

This is a simulation: all indicators are calculated in the browser. Buttons do not send commands to real equipment. You can pause the process, reset it to the initial state, or switch to "Mimic scheme only" mode; return with Esc key.

Open demo in a separate tab 15

Use the demo as a basis for your own scheme. Click "Export demo for editor", and in REGMIK SSD open "Mimic schemes 11 Import/Export" and import the JSON. The scheme is added as a new editable tab: replace labels, arrange equipment, and assign your object's channels.

REGMIK SSD for iPhone and iPad

The REGMIK SSD mobile app complements REGMIK SSD Web Console: equipment indicators, measurement history, alarms, and allowed commands are available from iPhone or iPad. Ukrainian and English languages, light and dark themes are supported.

  • Device list with search, filters by object and status, selected devices.
  • Charts for 1 hour, 24 hours, 7 and 30 days, and export history to CSV.
  • Alarm log, operator event acceptance, and push notifications after server setup.
  • Saving last indicators for offline viewing with update time marking.
  • Role-based control, parameter write confirmation, and command log.
  • Demo mode for familiarization without equipment connection.

Adaptation for iPhone Duo

The interface is prepared for different screen widths: on wide screens, the device list and selected device are shown side by side; on compact ones - sequentially. Supports portrait and landscape orientations and preserves selected device on resize.

Connection and access

The app requires iOS 17 or later and an SSD server account with mobile API enabled. Devices connect to SSD, including via PI Ethernet and RS-485/Modbus. For real devices, configured channels and verified register maps are necessary. Access to local server from iPhone requires HTTPS.

REGMIK SSD can be used with a cloud server or own server installation. The mobile app is being prepared for App Store publication; download link appears after Apple approval.

Open REGMIK SSD Web Console

REGMIK SSD: Privacy and Data

Updated October 11, 2026. This page describes data processing in the REGMIK SSD mobile app for iPhone and iPad.

App and your server

REGMIK SSD connects to an HTTPS server whose address you select on the login screen. By default, this is ssd.regmik.ua. If you use your organization's server, its administrator defines access, settings, retention periods, and data processing of that server.

What data is processed

  • For login: login, organization number, password, and account identifier. Needed for authentication and rights verification. Session tokens are stored in device Keychain.
  • For access recovery: the email address you enter is sent to the selected server for sending a recovery letter.
  • For operation: device and channel data, indicators, measurement history, alarms, allowed commands, settings, and action log associated with the account.
  • For push: with your permission - APNs token, installation identifier, notification settings, and language. They link to your session to deliver alarms to the intended user.

Purpose and recipients

This data is used for app operation, access protection, command logging, and notifications. The app contains no advertising or third-party analytics SDKs and does not use data for advertising tracking. The app does not request geolocation, contacts, camera, or microphone.

Request recipients are the SSD server you chose. Push uses Apple Push Notification service (APNs); password recovery uses the server operator's mail service. Detailed technological data is not included in push text on the lock screen. If you export CSV, the recipient or saving location is chosen independently via the system "Share" menu.

Local storage

Last indicators are cached separately per server, organization, and user for offline viewing. Cache expires up to 7 days, protected by iOS mechanisms and excluded from backup. Account logout or session rejection deletes that account's cache; logout revokes session and push subscription on server. App exit does not delete server measurement history or organization logs.

Data management and inquiries

Notifications can be disabled in app profile or iOS settings. Accounts are created by organization administrator; no new account registration in the app. For clarifications, corrections, or deletion of account and related server data, contact your organization's administrator. For REGMIK services, write to support@regmik.ua. Specify server and organization in inquiry; do not send password.

Server measurement and log retention depend on server operator settings and obligations. Deletion requests are considered per organization rights and mandatory retention requirements.

Demo mode

The standalone demo version uses fictional data, needs no account, and does not send commands to real equipment.

REGMIK Contacts

NVF "REGMIK", Ukraine, Chernihiv region, Rivnopillia village, 2-B Soniashna St. Technical support: support@regmik.ua, +380504654053. Contacts 16 REGMIK General Privacy Policy.

FAQ

Questions and answers

What is the purpose of the REGMIK SSD system?
REGMIK SSD is designed for collecting, storing, analyzing, and visualizing technological data. REGMIK SSD Web Console and mobile app help control equipment and respond to alarms.
Which protocols and data sources does REGMIK SSD Web Console support?
REGMIK SSD Web Console supports Modbus/TCP, OPC UA, MQTT, file and logger sources, and Edge-agent operation on the site.
How are data visualization and control implemented in REGMIK SSD?
Data in the system is visualized as charts, monitor cards, tables, and technological process mimic schemes. Remote control and device configuration via web interface are also supported.
What security and notification features are implemented in REGMIK SSD?
The system provides multi-user access with roles (Administrator, Engineer, Operator, Viewer), supports event logs, change audits, notifications via Telegram, email, SMS, webhook, and sound alarms.
How does REGMIK SSD handle data storage and export?
REGMIK SSD stores data in PostgreSQL. The web version has tools for configuration export and backup. The mobile app exports measurement history in CSV with UTC time.

Reviews

Customer reviews

There are no reviews yet.

Only verified customers can add reviews.

Open customer cabinet