REGMIK product

Regulator for Generator Control RD2-06

Price
5,150 UAH
Availability
In stock

The two-channel regulator with generator control function RD2-06 allows controlling the start/stop of the generator by a set program, measuring temperature and generator voltage during operation.

Back to catalog

Specifications

Description

The two-channel regulator with generator control function RD2-06 is designed to receive and convert signals coming from two sensors (temperature and generator voltage). As temperature sensors, resistance temperature detectors (RTD) can be used, and as voltage sensors – sensors with a standardized output current signal.

Resistance temperature detectors RTD (temperature sensors TCM – 50M, 100M; TSP – Pt100, Pt500, Pt1000) are intended for measuring the temperature of the ambient environment, liquid, gaseous, and bulk chemically harmless media, as well as the surface of solid bodies in various industries.
Temperature is the most commonly measured parameter, and overheating is one of the most negative factors in equipment operation, so there are many ways and places to apply temperature sensors.

Main functions of the two-channel regulator with generator control function RD2-06:

  • measurement of temperature on two channels using standard sensors: resistance temperature detector [RTD] and sensors with standardized output current signals 0..5 mA, 0(4)..20 mA [AT];
  • display on the built-in LCD of current parameter values in manual and automatic modes;
  • control of generator start/stop according to a set program;
  • data exchange with a personal computer via USB and RS-485 interfaces (ModBus RTU protocol);
  • generation of an "Error" signal;
  • galvanic isolation of input/output stages and USB, RS-485 interfaces – 1000 V.
The regulator for generator control RD2-06 is designed for DIN-rail mounting.

REGMIK

Downloads

FAQ

Questions and answers

What sensors are used with the RD2-06 regulator?
The RD2-06 regulator is connected to two sensors: a resistance temperature detector (RTD) for measuring temperature and a sensor with a standardized output current signal for measuring generator voltage.
Does the RD2-06 support generator start and stop control?
The RD2-06 regulator can control the start and stopping of the generator according to a set program, providing automatic generator control.
How does the RD2-06 measure temperature?
Temperature is measured on two channels using standard sensors: resistance temperature detectors (RTD) and current sensors with signals of 0..5 mA or 0(4)..20 mA.
Does the regulator display current parameter values?
The RD2-06 is equipped with a built-in LCD that displays current parameter values in manual and automatic modes.
What communication interfaces does the RD2-06 support?
For data exchange, the regulator has USB and RS-485 interfaces with support of the ModBus RTU protocol and galvanic isolation of 1000 V.

Reviews

Customer reviews

There are no reviews yet.

Only verified customers can add reviews.