Two-channel measurer I2-01
- Price
- 3,600 UAH
- Availability
- Backorder
DISCONTINUED!!!
Replacement RP2-U
Two-channel measurer/indicator with alarm output. Standard sensors TO, PT, AN, AT can be used as input sensors.
The two-channel measurer I2-01 has an alarm output and is designed to receive and convert one or two input analog signals into physical quantities (temperature, humidity, pressure, level, etc.) with subsequent display of the obtained values on a built-in digital indicator.
The device has two independent measurement channels and is produced in two power supply versions: AC mains 90..240V (IPI) or DC source 12..24V (IP24).
It is also possible to equip the device with two indicators to simultaneously display values from two channels.
- Temperature measurement using resistance temperature detectors (RTD - 50M, 100M; RTD - 50P, 100P, Pt100, Pt500, Pt1000), thermocouples (TXK, TXA, TXJ, etc.), sensors with standardized current output AT (0..5 mA, 0..20 mA, 4..20 mA) and voltage output AN (0..1 V, 0..5 V, 0..10 V);
- Displaying measured values on the built-in LED digital indicator (two-channel digital temperature indicator);
- Calculating and displaying on the second channel mathematical functions of two measured quantities (sum, difference, average, minimum, maximum);
- Calculating and displaying humidity by psychrometric method on the second channel (T1 - dry thermometer, T2 - wet thermometer);
- Function for calculating and displaying the square root of the measured quantity (e.g., for instantaneous flow measurement from AN and AT sensors);
- Scaling measurement scale (for AN and AT sensors);
- Light indication of operating modes (sensor alarm, programming);
- Software adjustment of conversion characteristics (slope, offset);
- Digital filtering of measurements (filter depth - up to 10 measurement periods);
- Digital calibration of input channels;
- Changing the display update period of the measured value;
- Programming with buttons on the front panel of the device;
- Parameter protection by password;
- Saving settings when power is off;
- Built-in 24V, 100mA power supply for active sensors in modifications with AN and/or AT;
- RS-485 Modbus RTU interface (optional).
| I[N1]-01[N2]TO,[N3]PT,[N4]ANx,[N5]ATx/[N6]OC,[N7]R,[N8]OS-2I- RS-485 - IPx– Panel | ||||||||
| I2 - 2TC-2I- RS-485 – IPI – Panel | ||||||||
| I | 2 | 2TC | 2I | RS-485 | IPI | Panel | ||
| Device type: I - measurer | ||||||||
| [N1] - number of measurement channels: 1, 2, 4, 8, | ||||||||
| 01 - alarm output in the two-channel measurer | ||||||||
| Number and types of input sensors: [N2] - number of TO [N3] - number of PT [N4] - number of sensors with AN (AN1 - 0 to 1 V; AN2 - 0 to 10 V; AN3 - 0 to 5 V) [N5] - number of sensors with AT (AT1 - 0 to 5 mA; AT2 - 0 to 20 mA; AT3 - 4 to 20 mA) | ||||||||
| Number and types of output devices: [N6] - number of OC – open collector [N7] - number of R - relay [N8] - number of OS - optoisolator | ||||||||
| Number of indicators: 2I - 2 four-digit seven-segment indicators | ||||||||
| Communication interface with PC: RS-485 | ||||||||
| Device power supply type: IPI - powered from AC mains nominal 90..240V, IP24 - powered from DC source nominal 12..24V | ||||||||
| Enclosure type: Panel - panel-mounted | ||||||||