REGMIK product

Temperature sensors TSM-105, TSP-105, TXA-105, TXK-105, TZhK-105

Price
807 UAH
Availability
In stock

Temperature sensors TSM-105, TSP-105, TXA-105, TXK-105, TZhK-105 group 1 are designed to measure the temperature of ambient air, liquid, gaseous and bulk chemically non-aggressive media in various industries.

Back to catalog

Specifications

Description

Temperature sensors TSM-105, TSP-105, TXA-105, TXK-105, TZhK-105 group 1 are designed to measure the temperature of ambient air, liquids, gaseous and bulk chemically non-aggressive media in various industries.

Temperature is the most commonly measured parameter, and overheating is one of the most negative factors in equipment operation, therefore there are many methods and places to use temperature sensors.

The operating principle of resistance thermometers is based on the change in electrical resistance of conductors and semiconductors depending on temperature. The material from which such a sensor is made should have a high temperature coefficient of resistance, preferably a linear dependence of resistance on temperature, good reproducibility of properties, and inertness to environmental influences. Platinum exhibits these properties to the greatest extent; copper to a somewhat lesser degree.

Thermocouples are exclusively differential temperature sensors. They generate an electrical signal proportional to the temperature difference between two different points. Therefore, the junction (weld) used to measure the required temperature is called the "hot" junction, and the other unavoidable junction is called the "cold" junction.

Resistance thermometers (temperature sensors) of group 1 are designed for measuring the temperature of ambient air, liquid, gaseous and bulk chemically non-aggressive media, as well as the surface of solid bodies in various industries.

Classification of temperature sensors TSM-105, TSP-105, TXA-105, TXK-105, TZhK-105 REGMIK by type of measuring (sensitive) element

  • - resistance thermometers (thermometers):
  • - resistance thermometers TSM (sensor TSM)
  • - resistance thermometers TSP (sensor TSP)
  • - thermoelectric converters (thermocouples):
    • thermocouples TXA
    • thermocouples TXK
    • thermocouples TZhK
  • semiconductor converters — TP.

Main technical specifications of temperature sensors 105:

  • Accuracy classes — A, B, C (for RT), 1, 2 (for TC);
  • CE wiring scheme — two-, three-, four-wire;
  • By CE type they are divided into
    • resistance thermometers (50M, 100M, 50P, 100P, Pt100, Pt500, Pt1000, Pt2000, Pt10000),
    • thermoelectric converters (thermocouples TXA (K), TXK (L), TZhK),
    • semiconductor (DS18B20);
  • Protective fitting material — steel 12X18H10T;
  • Protection rating against dust and water — IP54;
  • Thermometer design — non-disassemblable;
  • Insulation resistance — not less than 100 MOhm.

Temperature sensors TSM-105, TSP-105, TXA-105, TXK-105, TZhK-105 can be manufactured according to individual customer requirements.

Additional information

Modifications

TSP - 101 - Pt100 B 3x1 - D6 L150 - 40 - 500 M20x1.5 S22 B12 (-40…180)
TSP 1 01 Pt100. B. 3x1 D6 L150 40 500 M20x1.5 S22 B12 (-40...180)
Type: TSM, TSP, TXA, TXK, TZhK, TP (semiconductor)
Group: 0 - immersion; 1 - immersion with cable leads; 2 - surface; 3 – air.
TO Modification:
Modification designation (group) Permissible values yy
0yy 01, 02, 03, 04, 11, 12
1yy 01, 02, 03, 04, 05, 06, 07, 08
2yy 02, 03, 04, 04r, 05, 05r, 06, 07, 09
3yy 01, 02, 03, 03p, 07
CE Type: TSP – 10P, 50P, 100P, 1000P, Pt10, Pt50, Pt100, Pt500, Pt1000; TSM - 10M, 50M, 100M, 500M, 1000M
Tolerance class: TSP - AA, A, B, C; TSM - A, B, C
Sensitive element wiring scheme: PxN, where: P – number of leads; N - number of CE according to drawing 1.1
Installation part diameter, D, mm: according to dimensional drawing
Installation part length, L, mm: according to dimensional drawing
External part length, Lн, mm: according to dimensional drawing
Lead length, Lв, mm: according to dimensional drawing
Thread type of fitting: according to dimensional drawing
Fitting nut size, mm: according to dimensional drawing
Bayonet size, mm: according to dimensional drawing
Temperature range, °C: see table 1.10

REGMIK

Downloads

FAQ

Questions and answers

For which media are the temperature sensors TSM-105, TSP-105, TXA-105, TXK-105, TZhK-105 intended?
Temperature sensors TSM-105, TSP-105, TXA-105, TXK-105, TZhK-105 are designed to measure the temperature of ambient air, liquid, gaseous and bulk chemically non-aggressive media, as well as the surface of solid bodies in various industries.
What is the working principle of resistance thermometers in temperature sensors?
The operating principle of resistance thermometers is based on the change in electrical resistance of conductors and semiconductors depending on temperature. The sensor material must have a high temperature coefficient of resistance, linear dependence of resistance on temperature, and be inert to environmental influences. Platinum or copper are most commonly used.
What are the main technical characteristics of the 105 series temperature sensors?
Temperature sensors may have tolerance classes A, B, C for resistance thermometers and 1, 2 for thermocouples. The wiring scheme of the sensitive element can be two-, three- or four-wire. Protective fitting material is steel 12X18H10T, protection rating is IP54.
Is it possible to order temperature sensors TSM-105, TSP-105, TXA-105, TXK-105, TZhK-105 with custom specifications?
Temperature sensors TSM-105, TSP-105, TXA-105, TXK-105, TZhK-105 can be manufactured according to individual customer requirements, taking into account the necessary parameters and design features.