REGMIK product

Temperature sensors 202

Price
445 UAH
Availability
In stock

Temperature sensors of group 202, type 2 are intended for measuring the surface temperature of solid bodies in various industries. They have small dimensions, improved thermal inertia indicators, and do not require complex installation during mounting on the object. Temperature is the most common parameter for measurement, and overheating is one of the most harmful factors in equipment operation, thus there are many options ... Read more Temperature sensors 202

Back to catalog

Specifications

Description

Temperature sensors of group 202, type 2 are designed for measuring the surface temperature of solid bodies in various industrial fields. They feature small dimensions, improved thermal inertia characteristics, and do not require complex installation when mounted on the object.

Temperature is the most common measurement parameter, and overheating is one of the most harmful factors in equipment operation. Therefore, there are many variants and application areas for temperature sensors.

The operating principle of resistance thermometers is based on the change in electrical resistance of conductors and semiconductors depending on temperature. The material from which the sensor is made must have a high temperature coefficient of resistance, a linear resistance-temperature relationship (if possible), good reproducibility of properties, and inertness to environmental influences. Platinum best meets these requirements, copper somewhat less so.

Thermocouples are differential temperature sensors. They generate an electrical signal proportional to the temperature difference between two points. The junction (weld) used for temperature measurement is called the "hot" junction, and the other junction which inevitably contacts is called the "cold" junction.

Classification of 202 REGMIK temperature sensors by type of sensing element

  • Resistance thermometers (thermometers) – TSM, TSP;
  • Thermoelectric converters (thermocouples) – TXA, TXK, TZHK;
  • Semiconductor converters – TP.

Main technical characteristics of 202 temperature sensors:

  • Sensing element wiring scheme – two-, three-, four-wire;
  • Type of sensing element:
    • resistance thermometers (RTD, thermal resistors, thermometers) (50M, 100M, 50P, 100P, Pt100, Pt500, Pt1000, Pt2000, Pt10000);
    • thermoelectric converters (TC, thermocouples) (TXA (K), TXK (L));
    • semiconductors (DS18B20);
  • Degree of protection against dust and water – IP54;
  • Design of thermometers (temperature sensors) – non-disassemblable;
  • Insulation resistance – not less than 100 MΩ;
  • Accuracy classes – A, B, C (for RTD), 1, 2 (for TC).

Additional information

Modifications

TSP - 101 - Pt100 B 3x1 - D6 L150 - 40 - 500 M20x1.5 S22 B12 (-40…180)
TSP 1 01 Pt100. B. 3x1 D6 L150 40 500 M20x1.5 S22 B12 (-40...180)
Type: TSM, TSP, TXA, TXK, TZHK, TP (semiconductor)
Group: 0 - immersion; 1 - immersion with cable outputs; 2 - surface; 3 - air.
Modification of TO:
Modification designation (group) Allowed values aa
0aa 01, 02, 03, 04, 11, 12
1aa 01, 02, 03, 04, 05, 06, 07, 08
2aa 02, 03, 04, 04r, 05, 05r, 06, 07, 09
3aa 01, 02, 03, 03p, 07
Sensing element type: TSP – 10P, 50P, 100P, 1000P, Pt10, Pt50, Pt100, Pt500, Pt1000; TSM - 10M, 50M, 100M, 500M, 1000M
Accuracy class: TSP - AA, A, B, C; TSM - A, B, C
Connection scheme of sensing element leads: PxN, where: P – number of leads; N - number of sensing elements as per figure 1.1
Diameter of mounting part, D, mm according to dimensional drawing
Length of mounting part, L, mm according to dimensional drawing
Length of external part, Ln, mm according to dimensional drawing
Length of leads, Lv, mm according to dimensional drawing
Thread type of fitting: per dimensional drawing
Size of fitting nut, mm per dimensional drawing
Size of bayonet, mm per dimensional drawing
Temperature range, °C: per table 1.10

REGMIK

Downloads

FAQ

Questions and answers

What are the temperature sensors of type 202 type 2 designed for?
Temperature sensors of group 202 type 2 are designed to measure the surface temperature of solid bodies in industry. They have small dimensions, improved thermal characteristics, and are easy to install.
What types of sensitive elements are used in sensors 202?
Sensors 202 use various types of sensitive elements: resistance temperature detectors (RTD, TSP), thermoelectric converters (TXA, TXK, TJK), and semiconductor (TP).
What protection rating do the 202 temperature sensors have and what is their design?
The sensors have a protection rating of IP54, which provides protection against dust and water splashes. The design is non-disassemblable, with insulation resistance not less than 100 MΩ.
What connection scheme options and accuracy classes are available for sensors 202?
The sensors can have connection schemes for the sensitive element of two-, three-, or four-wire types, and accuracy classes for resistance temperature detectors are A, B, C, and for thermocouples – 1, 2.
How to choose the appropriate modification of the 202 temperature sensor?
Various modifications of the 202 sensors are designated by groups (0,1,2,3), types of sensitive elements, and have parameters such as diameter and mounting part length specified in the technical tables.