Single-channel temperature controller RD1 measures, monitors, and regulates temperature or other physical quantities using standard sensors. Resistance thermometers, thermoelectric converters, and sensors with standardized current or voltage output signals can be used as sensors.

Back to catalog

Specifications

Description

Single-Channel Temperature Controller RD1

The RD1 temperature measuring/regulating device performs two-position regulation of the input physical quantity, automatically monitors the status of the input sensor, detects when the measured input value is outside the set measurement range, verifies the correct input of parameters and calibration of the device. Based on the monitoring results, an "Error" signal is generated.
The controller is available in two versions: AC mains voltage 90..240V (IPi) or DC power supply 12..24V (IP24). It is also possible to manufacture models with two indicators to simultaneously display current, set values and alphanumeric information.

Purpose

The two-position single-channel temperature controller RD1 is designed for measuring, indicating and regulating the temperature of various media in refrigeration equipment, drying chambers, industrial/domestic ovens, and other technological equipment, as well as for measuring and controlling other physical quantities (level, flow, pressure, humidity, etc.) by two-position control using sensors with standardized analog signals.

Functions and modes of operation of the RD1 temperature controller

  • Measurement of temperature (or other physical quantities) of objects using resistance thermometers (temperature sensors) TCM (50M, 100M) and TSP (50P, 100P, Pt100, Pt500, Pt1000), thermocouples (TXK, TXA, TJK, etc.), sensors with standardized output current signals AT (0..5 mA, 0..20 mA, 4..20 mA) and voltage AN (0..1 V, 0..5 V, 0..10 V);
  • Control of input quantity by two-position control law;
  • Display of measured value on built-in LED display (digital temperature indicator);
  • Scaling of measurement scale (for AN and AT sensors);
  • Visual indication of operating modes (sensor failure, programming);
  • Software adjustment of transformation characteristic parameters (slope, offset);
  • Digital filtering of measurements (filter depth up to 10 measurement periods);
  • Change of measurement display update rate;
  • Digital calibration of input channel;
  • Programming by buttons on the front panel of the device;
  • Password protection of parameters;
  • Settings retention upon power off;
  • Built-in power source = 24V, 100mA for active sensors in versions with AN and/or AT;
  • RS-485 ModBus RTU interface.

The RD1 temperature controller has a more advanced version — a universal device RP2-U. RP2-U is produced both for panel mounting and DIN rail installation. The new version fully replaces the functionality of the two-position single-channel temperature controller RD1 and additionally offers several added features.

Additional information

Modifications

Bistable Modifications
T[N1] [N2]TO,[N3]PT,[N4]ANx,[N5]ATx/ [N6]OK,[N7]R,[N8]OS-2I- RS-485 - IPx– Panel
RD2 - 1TC, 1PT/2R-2I- RS-485 – IPi – Panel
RD 2 1PT,1TC 2R 2I RS-485 IPi Panel
Device type: RD - bistable controller
[N1] - number of measurement/control channels: 1, 2, 3, 4, 8
Number and types of input sensors: [N2] - number of TC [N3] - number of PT [N4] - number of sensors with AN (AN1 - 0 to 1 V; AN2 - 0 to 10 V; AN3 - 0 to 5 V) [N5] - number of sensors with AT (AT1 - 0 to 5 mA; AT2 - 0 to 20 mA; AT3 - 4 to 20 mA)
Number and types of output devices: [N6] - number of OK – open collector [N7] - number of R - relay [N8] - number of OS - optotriac
Number of indicators: 2I - 2 four-digit seven-segment indicators
Communication interface with PC: RS-485
Device power supply type: IPi - powered from AC mains 90..240 V; IP24 - powered from DC source 12..24 V
Enclosure type: Panel - panel mount

Additional information

Specifications

Types of Input Devices
Input Primary Converter
Measuring Range, °C
Modification
Sensor Code
Type
Characteristic Curve
TC per DSTU 2858-94
01
TCM 50 W=1.4260
50M
-50..+200
02
TCM 50 W=1.4280
50M
-50..+200
03
TSP 50 W=1.3850
Pt50
-50..+600
04
TSP 50 W=1.3910
50P
-50..+600
05
TCM 100 W=1.4260
100M
-50..+200
06
TCM 100 W=1.4280
100M
-50..+200
07
TSP 100 W=1.3850
Pt100
-50..+600
08
TSP 100 W=1.3910
100P
-50..+600
09
TSP 46 W=1.3910
group 21
-50..+600
71
TSP 500 W=1.3850
Pt500
-50..+600
72
TSP 1000 W=1.3850
Pt1000
-50..+600
TC per DSTU 2837-94
10
TXK
L
-30..+600
11
TXA
K
-50..+1200
12
TJK
J
-30..+850
13
TPP 10
S
0..+1750
15
TPR
B
+200..+1800
16
TVR
A-1
0..+2500
AN
21
Voltage AN1 (0-1V)
-
User defined
22
Voltage AN2 (0-10V)
23
Voltage AN3 (0-5V)
AT
31
Current AT1 (0-5 mA)
-
User defined
32
Current AT2 (0-20 mA)
33
Current AT3 (4-20 mA)
Types of Output Devices
Output Device
Load Capacity
Electromagnetic Relay (R)
5A 220V
Optotriac Coupler (OS)
100mA 220V
Optotransistor Coupler (OK)
150mA 80V
Power Triac (S)
2A 220V
Main Technical Specifications of the Temperature Controller
Specification Name
Value
Rated Supply Voltage, V
220 AC
12..24 DC
Allowed Supply Voltage Deviation, %
±10
Power Consumption, W
6
Setpoint, °C
-50..2500
Hysteresis, °C
0..1300
Lower Limit of Tolerance Range, °C
-50..2500
Upper Limit of Tolerance Range, °C
-50..2500
Conversion Characteristic Offset, °C
-99.9..999.9
Cold Junction Temperature Compensation, °C
-99.9..99.9
Conversion Characteristic Slope
0.001..9.999
Digital Filter
0.1..99.9
Averaging Time, Number of Measurement Periods
0..9
Output Device Turn-On Delay, s
0..255
Output Device Turn-Off Delay, s
0..255

REGMIK

Downloads

FAQ

Questions and answers

What applications is the single-channel temperature controller RD1 intended for?
The single-channel temperature controller RD1 is designed for measuring, indicating, and two-position control of temperature of various media in refrigeration equipment, drying chambers, ovens, as well as for controlling other physical quantities (level, flow, pressure, humidity) using appropriate sensors.
Which types of sensors can be connected to the RD1 controller?
RD1 supports connection of resistance thermometers (TCM, TSP, Pt100, Pt500, Pt1000), thermocouples types TXK, TXA, TJK, etc., as well as sensors with standardized current output signals (0..5 mA; 0..20 mA; 4..20 mA) and voltage output (0..1 V; 0..5 V; 0..10 V).
What do the IPi and IP24 power modifications mean for the RD1 controller?
RD1 has two power supply modifications: powered from AC mains voltage 90..240 V (designation IPi) and powered from DC source 12..24 V (designation IP24).
What control and calibration features does the RD1 controller support?
The controller allows scaling of the measurement scale for sensors with analog voltage or current, software changing of transformation characteristic parameters (slope, offset), digital filtering of the signal, as well as setting delays for switching output devices on and off.
How are measured and set values displayed on the RD1 controller?
RD1 has a built-in LED digital indicator to display the current value, and can also have two indicators for simultaneous display of current and set values along with alphanumeric information.

Reviews