REGMIK product

Temperature Sensor TSPU-002 (4..20mA, 0..10V, RS-485)

Price
2,870 UAH
Availability
In stock

Temperature sensors with unified output signal allow connection of temperature sensors to any devices with inputs 4..20 mA, 0..10 V or RS-485.

Back to catalog

Specifications

Description

Temperature sensor with a unified output signal TSPU-002 is designed to measure and convert the measured value into a 4..20mA, 0..10V, or RS-485 signal. TSPU-002 sensors are used for measuring ambient temperature, as well as temperature of liquid, gaseous, and bulk media in various industries.

The operating principle of temperature sensors with unified output signal TSPU-002 (4-20mA, 0..10V) is based on the property of copper (platinum) to change electrical resistance depending on the temperature of the medium. The conversion unit transforms the resistance value into a current signal (voltage signal) proportional to the temperature value. The change in current (voltage) is recorded by the secondary device into which the PTU is integrated in the measurement circuit.

The TSPU-002 construction is non-disassemblable.

Thermoresistors differ by the material of the sensitive element: TSM - copper, TSP - platinum. In turn, PMM is divided into 50M and 100M, and TSP - into 100P, Pt100. The difference between TSM and TSP lies only in the measured temperature range: TSM (-50..+180C), and TSP (-50..+500C).

The 4-20 mA (or 0-20 mA) output provides enhanced resistance to electrical interference and has low signal losses when using very long cables; it can be transmitted losslessly over hundreds of meters. As an additional benefit, the 4-20 mA signal provides error state detection since even at its lowest value the sensor remains active. That is, at the extreme "zero" position, the sensor still outputs a 4 mA signal, and if the value ever drops to 0 mA, something is wrong with the device. In contrast, for sensors with 0-10 V output, a 0 V value may indicate either the zero position or that the sensor has simply stopped functioning.

Temperature sensors with unified output signal TSPU-002:

  • Convert resistance value into a current signal (4..20 mA) or voltage signal (0..10 V), proportional to the temperature value;
  • Measure and transmit measured temperature value via RS-485 interface (protocol ModBus RTU).

Features of TSPU-002 sensors:

  • Minimum installation part length – 60 mm;
  • Current consumption, no more than - 40 mA;
  • DC supply voltage - (20..28) V;
  • Protective fitting material - 12X18H10T stainless steel;
  • Galvanic isolation between converter and measuring equipment;
  • Enclosure protection rating - IP65.

Additional information

Modifications

Sensor Model Installation Part Length, L, mm
60 120 160 200 250 320 400 500 630 800 1000 1250 1500 2000
PTU TSPU 002d-T-0.5 1268 1274 1280 1286 1294 1302 1310 1318 1356 1394 1440 1486 1532 1600
PTU TSPU 002d-RS-485-0.5 1438 1444 1450 1456 1464 1472 1480 1488 1526 1564 1610 1656 1702 1770
PTU TSPU 002d-T-0.2 1333 1339 1345 1351 1359 1367 1375 1383 1421 1459 1505 1551 1597 1665
PTU TSPU 002d-RS-485-0.2 1503 1509 1515 1521 1529 1537 1545 1553 1591 1629 1675 1721 1767 1835
PTU TSPU 002b-T-0.5 1173 1179 1185 1191 1199 1207 1215 1223 1261 1299 1345 1391 1437 1505
PTU TSPU 002b-RS-485-0.5 1343 1349 1355 1361 1369 1377 1385 1393 1431 1469 1515 1561 1607 1675
PTU TSPU 002b-T-0.2 1238 1244 1250 1256 1264 1272 1280 1288 1326 1364 1410 1456 1502 1570
PTU TSPU 002b-RS-485-0.2 1408 1414 1420 1426 1434 1442 1450 1458 1496 1534 1580 1626 1672 1740
b - large carbolite head; d - duralumin head; T - sensor temperature resistance converted to current; RS-485 - sensor resistance conversion to RS-485 (protocol ModBus RTU).

REGMIK

Downloads

FAQ

Questions and answers

For which media is the TSPU-002 temperature sensor intended?
The temperature sensor TSPU-002 is designed for measuring the temperature of the ambient environment, liquids, gaseous, and bulk media in various industries.
What types of output signals does the TSPU-002 sensor support?
The sensor supports output signals in the form of current 4..20 mA, voltage 0..10 V, or digital RS-485 interface with ModBus RTU protocol.
What are the key technical construction characteristics of the TSPU-002 sensor?
The sensor has a minimum mounting part length of 60 mm, a housing made of 12X18H10T material with an IP65 protection rating, and a current consumption not exceeding 40 mA at a supply voltage of 20–28 V DC.
How does the TSPU-002 temperature sensor work?
The sensor's operating principle is based on the change in electrical resistance of copper or platinum, the sensitive element, depending on the temperature of the medium, while the conversion unit converts this resistance into a corresponding output signal (4..20 mA, 0..10 V, or RS-485).
How to interpret the 4-20 mA signal from the TSPU-002 sensor and is it possible to detect a malfunction?
The 4-20 mA signal corresponds to the temperature range, where 4 mA is the minimum temperature value, and 0 mA indicates a sensor malfunction, allowing easy detection of an error in operation.

Reviews

Customer reviews

There are no reviews yet.

Only verified customers can add reviews.

Open customer cabinet