REGMIK product

PID Single-Channel Controller RP1

Price
3,508 UAH
Availability
Backorder

DISCONTINUED!!! POSSIBLE MANUFACTURE BY CONTRACT!

Replacement RP2-U

The PID single-channel controller RP1 is designed for multi-stage control and management of temperature regimes of various technological processes in the production of meat and sausage products, bakery industry, incubators, thermal chambers, etc.

Back to catalog

Specifications

Description

The PID single-channel controller RP1 regulates the input physical quantity based on the proportional-integral-derivative (PID) law, automatically monitors the state of the input sensor, the input quantity being outside the set measurement range, the correctness of parameter input, and the calibration of the device. Based on the monitoring results, an "Error" signal is generated.

The PID controller enables the following functions:

  • Measurement of parameters of various objects using standard sensors (resistance temperature detectors (temperature sensors) TSM (50M, 100M) and TSP (50P, 100P, Pt100), thermocouples (TXK, TXA, TJK, etc.), sensors with standardized output current and voltage signals);
  • Display on built-in LED digital indicators of current and set parameter values;
  • Regulation of the physical quantity according to the proportional-integral-derivative (PID) law;
  • Light indication of the device operating mode;
  • Possibility to change the set value (setpoint) for the PID controller;
  • Operation in the mode of input quantity to analog signal converter;
  • Operation in manual analog signal setting mode;
  • Data exchange with a personal computer via RS-485 interface;
  • Generation of an "Error" signal;
  • Software modification of transformation characteristic parameters.

Manufacturing modifications:

- Panel mount;
- Power supply from 220V AC mains and from 12..24V DC source;
- Types of input signals TO, PT, AN, and AT;
- Types of output signals:
0..10V (AN2);
4..20mA (AT3).

You may be interested in the new line of devices that can replace the PID controller:

- PID controller RP2-U;
- Universal dual-channel device RP2-M.

Additional information

Characteristics

Types of Input Devices
Input Primary Converter
Measurement Range, °C
Modification
Sensor Code
Type
NSK
TO according to DSTU 2858-94
01
TSM 50 W=1.4260
50M
-50..+200
02
TSM 50 W=1.4280
50M
-50..+200
03
TSP 50 W=1.3850
Pt50
-50..+600
04
TSP 50 W=1.3910
50P
-50..+600
05
TSM 100 W=1.4260
100M
-50..+200
06
TSM 100 W=1.4280
100M
-50..+200
07
TSP 100 W=1.3850
Pt100
-50..+600
08
TSP 100 W=1.3910
100P
-50..+600
09
TSP 46 W=1.3910
grp.21
-50..+600
71
TSP 500 W=1.3850
Pt500
-50..+600
72
TSP 1000 W=1.3850
Pt1000
-50..+600
TO according to DSTU 2837-94
10
TXK
L
-30..+600
11
TXA
K
-50..+1200
12
TJK
J
-30..+850
13
TPP 10
S
0..+1750
15
TPR
B
+200..+1800
16
TVR
A-1
0..+2500
AN
21
Voltage AN1 (0-1V)
-
Defined by user
22
Voltage AN2 (0-10V)
23
Voltage AN3 (0-5V)
AT
31
Current AT1 (0-5 mA)
-
Defined by user
32
Current AT2 (0-20 mA)
33
Current AT3 (4-20 mA)
Types of Output Devices
Output Device
Load Capacity
Electromagnetic Relay (R)
5A 220V
Thyristor Optocoupler (OS)
100mA 220V
Transistor Optocoupler (OK)
150mA 80V
Power Thyristor (S)
2A 220V
Voltage AN1
0..1V
Voltage AN2
0..10V
Voltage AN3
0..5V
Current AT1
0..5mA
Current AT2
0..20mA
Current AT3
4..20mA
Main Technical Specifications of the Temperature Controller
Specification Name
Value
Nominal Supply Voltage, V
220V AC
12..24V DC
Allowable Supply Voltage Deviation, %
±10
Power Consumption, W
6
Setpoint Value, °C
-50..2500
Hysteresis, °C
0..1300
Lower Limit of Tolerance Range, °C
-50..2500
Upper Limit of Tolerance Range, °C
-50..2500
Transformation Characteristic Offset, °C
-99.9..999.9
Cold Junction Temperature Compensation, °C
-99.9..99.9
Transformation Characteristic Slope
0.001..9.999
Digital Filter
0.1..99.9
Averaging Time, Number of Measurement Periods
0..9
Output Device Turn-On Delay, s
0..255
Output Device Turn-Off Delay, s
0..255

Additional information

Modifications

Modifications of PID Controllers with Analog Outputs
T[N1] [N2]TO,[N3]PT,[N4]ANx,[N5]ATx/ [N6] ANx,[N7] ATx -2I- RS-485 - IPx– Panel
RP1 – 1TC/1AN2-2I- RS-485 – IPI – Panel  
RP 1 1TC 1AN2 2I RS-485 IPI Panel
Device type: RP - PID controller
[N1] - number of measurement/control channels 1 2
Number and types of input sensors: [N2] - number of TO [N3] - number of PT [N4] - number of sensors with AN (AN1 - 0 to 1 V; AN2 - 0 to 10 V; AN3 - 0 to 5 V) [N5] - number of sensors with AT (AT1 - 0 to 5 mA; AT2 - 0 to 20 mA; AT3 - 4 to 20 mA)
Number and types of output devices: [N6] - number of voltage outputs AN (AN1 - 0 to 1 V; AN2 - 0 to 10 V; AN3 - 0 to 5 V) [N7] - number of current outputs AT (AT1 - 0 to 5 mA; AT2 - 0 to 20 mA; AT3 - 4 to 20 mA)
Number of indicators: 2I - 2 four-digit seven-segment indicators
PC communication interface: RS-485
Device power supply type: IPI - powered from AC mains nominal 90..240V I24 - powered from DC source nominal 12..24V
Housing type: Panel