The PID single-channel controller RP1 is designed for multi-stage control and management of temperature regimes of various technological processes in the production of meat and sausage products, bakery industry, incubators, thermal chambers, etc.
The PID single-channel controller RP1 regulates the input physical quantity based on the proportional-integral-derivative (PID) law, automatically monitors the state of the input sensor, the input quantity being outside the set measurement range, the correctness of parameter input, and the calibration of the device. Based on the monitoring results, an "Error" signal is generated.
The PID controller enables the following functions:
- Measurement of parameters of various objects using standard sensors (resistance temperature detectors (temperature sensors) TSM (50M, 100M) and TSP (50P, 100P, Pt100), thermocouples (TXK, TXA, TJK, etc.), sensors with standardized output current and voltage signals);
- Display on built-in LED digital indicators of current and set parameter values;
- Regulation of the physical quantity according to the proportional-integral-derivative (PID) law;
- Light indication of the device operating mode;
- Possibility to change the set value (setpoint) for the PID controller;
- Operation in the mode of input quantity to analog signal converter;
- Operation in manual analog signal setting mode;
- Data exchange with a personal computer via RS-485 interface;
- Generation of an "Error" signal;
- Software modification of transformation characteristic parameters.
Manufacturing modifications:
- Panel mount;
- Power supply from 220V AC mains and from 12..24V DC source;
- Types of input signals TO, PT, AN, and AT;
- Types of output signals:
0..10V (AN2);
4..20mA (AT3).
You may be interested in the new line of devices that can replace the PID controller:
- PID controller RP2-U;
- Universal dual-channel device RP2-M.
| 220V AC 12..24V DC | |
| Modifications of PID Controllers with Analog Outputs | |||||||
| T[N1] [N2]TO,[N3]PT,[N4]ANx,[N5]ATx/ [N6] ANx,[N7] ATx -2I- RS-485 - IPx– Panel | |||||||
| RP1 – 1TC/1AN2-2I- RS-485 – IPI – Panel | |||||||
| RP | 1 | 1TC | 1AN2 | 2I | RS-485 | IPI | Panel |
| Device type: RP - PID controller | |||||||
| [N1] - number of measurement/control channels 1 2 | |||||||
| Number and types of input sensors: [N2] - number of TO [N3] - number of PT [N4] - number of sensors with AN (AN1 - 0 to 1 V; AN2 - 0 to 10 V; AN3 - 0 to 5 V) [N5] - number of sensors with AT (AT1 - 0 to 5 mA; AT2 - 0 to 20 mA; AT3 - 4 to 20 mA) | |||||||
| Number and types of output devices: [N6] - number of voltage outputs AN (AN1 - 0 to 1 V; AN2 - 0 to 10 V; AN3 - 0 to 5 V) [N7] - number of current outputs AT (AT1 - 0 to 5 mA; AT2 - 0 to 20 mA; AT3 - 4 to 20 mA) | |||||||
| Number of indicators: 2I - 2 four-digit seven-segment indicators | |||||||
| PC communication interface: RS-485 | |||||||
| Device power supply type: IPI - powered from AC mains nominal 90..240V I24 - powered from DC source nominal 12..24V | |||||||
| Housing type: Panel | |||||||