Universal two-channel device RP2-T. PULSE COUNTER / UNIVERSAL TIMER / TIME RELAY.
UNIVERSAL TWO-CHANNEL COUNTER-TIMER
RP2-T
The universal two-channel counter-timer RP2-T is designed to replace an entire series of technological process controllers: pulse counters, universal timers, and time relays.
INFORMATION DISPLAY
The counter-timer uses a high-tech custom LED display that provides the user with clear and intuitive information. The display features a wide viewing angle, and readings are clearly visible even from a great distance in any lighting conditions.
VERSATILITY
Ability to connect various types of input signal sources — "dry contact", common collector, and others. The device has two analog outputs configurable for the required output range, as well as two discrete outputs and an alarm output.
CONSTRUCTION
The universal two-channel counter-timer RP2-T has an updated case with terminal connections, allowing convenient connection of input sensors and output devices, and ensures reliable mounting in the panel.
The housing is made of polycarbonate, which is flame-retardant.
CERTIFICATION
The universal two-channel counter-timer RP2-T complies with the requirements of the relevant technical regulations:
- Technical Regulation on Electromagnetic Compatibility of Equipment , approved by the Cabinet of Ministers of Ukraine Resolution No. 1077 dated December 16, 2015.
- Technical Regulation on Low-Voltage Electrical Equipment, approved by the Cabinet of Ministers of Ukraine Resolution No. 1067 dated December 16, 2015.
The device meets the requirements of relevant standards from the national standards list applied:
- DSTU EN 61326-1:2016, EN 55011:2016/A1:2017/A11:2020 — electrical equipment for measurement, control and laboratory use. Electromagnetic compatibility requirements;
- DSTU EN 61010-1:2014 — safety requirements for measuring, control and laboratory electrical equipment;
- DSTU EN 60529:2014 — degrees of protection provided by enclosures IP54.
In addition to the manufacturer's "internal production control" procedure (module A), an accredited conformity assessment body was involved: the State Enterprise "Ukrmetrteststandart" performed voluntary product certification and issued certificate of conformity No. UA.001.30.01054-21 dated 30.09.2021.
The universal two-channel counter-timer RP2-T complies with standards/normative documents and EU Directives: CE, 2014/30/EU (EMC), 2014/35/EU (LVD), 2014/53/EU (RED), 2011/65/EU (RoHS).
UNIVERSAL TWO-CHANNEL COUNTER-TIMER RP2-T: OPERATING MODES
- forward and reverse pulse counting;
- operation with encoder;
- flow meter;
- frequency meter;
- tachometer;
- dosing device;
- equipment operating time counter;
- universal timer;
- time relay.
UNIVERSAL TWO-CHANNEL COUNTER-TIMER RP2-T: TECHNICAL SPECIFICATIONS
Power supply
- 110...240 V AC, 50/60 Hz;
- 12...24 V DC.
Internal power supply unit
- 24 V DC, load capacity 60 mA.
Interfaces
- RS485 — ModBus RTU protocol;
- isolated RS485 — ModBus RTU protocol.
Inputs
- 2 inputs configurable depending on operating mode as counting or enable inputs;
- 2 run enable inputs for START / STOP / PAUSE / blocking output devices.
Discrete outputs
- electromechanical relay — 5A, 220 V AC;
- transistor optocoupler — 100 mA, at 60 V DC;
- triac optocoupler — 100 mA, at 220 V AC.
Alarm output
- transistor switch — 100 mA, at 60 V DC.
Analog outputs
- 0...5 mA, 0...20 mA, 4...20 mA — output signal type configurable by the user.
UNIVERSAL TWO-CHANNEL COUNTER-TIMER RP2-T: FEATURES
The universal two-channel counter-timer RP2-T has the following features:
- pulse counter operating frequency up to 20 kHz;
- parameter protection against unauthorized access;
- saving current operating modes in non-volatile device memory during power loss;
- ability to configure and run up to 70 universal timer programs simultaneously;
- universal timer operation with priority: month, week, day of the week, day, hour, minute, second;
- universal timer operation based on sunrise/sunset;
- ability to set up to 20 holidays and weekends during which the universal timer does not execute configured operating programs;
- configuration of up to 40 steps for the time relay;
- output control via RS-485 interface.
The device can also be supplied in a DIN-rail enclosure, the RP2-M model.
Other devices in the RP2 line:
— Universal two-channel meter/controller/pulse counter/time relay/logger RP2-M;
— Universal two-channel meter/controller RP2-U.
When designing an RS-485 network, please review the article
Correct RS-485 Network.
List of abbreviations: OK – optotransistor, OS – optosimistor, AC – analog current, P – electromagnetic relay
Information about modifications of the universal two-channel device RP2-T-x1x2x3, where:
x1 – output types:
0.– 2OS, 2AC; 1. – 2P, 2AC; 2. – 2OK, 2AC; 3. – 2OS; 4. – 2P; 5. – 2OK; 6. – no outputs.x2 – interfaces and non-volatile memory power supply:
0. – isolated RS-485 (ModBus RTU protocol); 1. – RS-485 (ModBus RTU protocol).x3 – type of power supply for the device:
0. – from AC mains nominal voltage 110-240 V AC; 1. – from DC voltage source nominal 12...24 V DC.What is the purpose of the RP2-T counter-timer?
What types of inputs and outputs does the RP2-T have?
What operating modes does the RP2-T counter-timer support?
What power supply options does the RP2-T support?
What are the features of the RP2-T housing design?
Reviews
Customer reviews
There are no reviews yet.
Only verified customers can add reviews.
Open customer cabinet